Kobra 2 neo - 190° PLA 60° Bed, retractions 1.05 mm 25mm/s, level and z offset ok, i use superslicer.
On don’t panic, just clean the bed, use glue stick on it and done
Your are my God of this printer your guide is amazing, I had trammed the X grantry multiple times, but my bed is warped, with that image the bed is now in perfect level and I’m printing in all of the volume :D
now im printing something, and just for trying i slow to 80mm/s travel Z moves , before was 120mm/s i think is working but the print is still in progress
ok im gonna try it tomorrow thanks
btw, Z axis recently lubed, im waiting for bolts and nuts to change the antibackslash nut and add an oldham coupler
Hahahaha, autolevel?, im more of permanent level, look at this https://imgur.com/a/3hoT8sC :D
You can use pronterface software and send M503 gcode to check the linear advance change to the value you put in the slicer
Just add M900 K(Value) in your slicer in the inicial custom gcode
In cura, I dont believe , in prusaslicer you can put a custom GCode before the last layer, just add it there
retraction and linear/pressure advance problem, adjust it and done same problem solved with both settings and z seam test stl
Is the nozzle enough far from bed to let the filament coming out?
Ok thanks, idk how to use klippler in my kobra 2 neo, maybe it could be a more adavanced topic for me, first printer + one month = newbie :D, but thanks for the 15 min that a time i cant find for the thermal expansion, now im working to make a better bed with kapton tape, i hope i can print anything again.
PD_ i try to use silicon spacers but with the stock threads of the printer i couldnt use the wheels to manual level :C
OK, Im doing that but i dont understand it for example let say in first point of the abl measured_z: -0.43 i assume that this is that my bed is far from the sensor, so i put kapton tape to close more this gap , but in the practice i do that and and the number now is -0.59 and when i do another autolevel is -0.08, i think im getting wrong values, is there any way to test my abl sensor is working properly?
Do you think these are normal values for a ABL?
0 1 2 3 4
0 -0.076 -0.107 -0.088 -0.147 -0.148
1 +0.095 +0.082 +0.124 +0.082 +0.129
2 +0.150 +0.085 +0.070 +0.122 +0.090
3 +0.125 +0.043 +0.001 -0.047 -0.025
4 +0.060 -0.049 +0.049 -0.055 -0.168
I follow your instructions in the kobra 2 neo insights web, and nothing, yesterday and I can’t level it
1 month with the same printer and the same issue
Welcome to anycubic
Temperature bed?, i use 100C and a lot of glue stick in bed, and without enclosure, prints good. Temp print 240 C same and just the tipical settings tunning flow rate, retractions, linear/pressure advance, I set my volumetric speed with a similar speed of your 500mm/s
mm maybe and overextrusion, did you calibrate your flow rate?
But the ending gcode is after the last layer not before it
Is there anyway to add a nozzle wipe on the last layer?
Cura